WESTERMO TELEINDUSTRI AB MA-44 DC Card Type Modem (asynchronous) Chip Set Unidentified I/O Options DC power, RS-232 serial port, RS-422/485 Maximum Modem Rate 38.4Kbps Data Modulation Protocol C/CCITT V.24/V.28, V.11 Error Correction/Compression Unidentified Data Bus External [Image] CONNECTIONS Function Label Function Label Power connector (terminal CN1 RS-232-C port CN3 block) Terminal block CN2 USER CONFIGURABLE SETTINGS Function Label Position » 115V AC enabled S1 On 230V AC enabled S1 Off 2-wire transmission S2/6 On » 4-wire transmission S2/6 Off » Factory configured - do not alter S2/7 Off » Factory configured - do not alter S2/8 Off » Factory configured - do not alter S2/9 Off DATA BIT SELECTION Setting S2/4 S2/5 9 On On » 10 On Off 11 Off On 12 Off Off TERMINATION WITH FAIL-SAFE SELECTION Setting S3/1 S3/2 S3/3 S3/4 Termination (4-wire) On On Off Off Termination (2-wire) Off Off On On » No termination Off Off Off Off DATA RATE SELECTION Setting S2/1 S2/2 S2/3 300bps Off Off Off 600bps On Off Off 1200bps Off On Off 2400bps On On Off 4800bps Off Off On » 9600bps On Off On 19200bps Off On On 38400bps On On On DIAGNOSTIC LED(S) LED Color Status Condition LED1 Unidentified On Power is on LED1 Unidentified Off Power is off LED2 Unidentified On Data is being received LED2 Unidentified Off Data is not being received LED3 Unidentified On Data carrier present LED3 Unidentified Off Data carrier not present - connection not established LED4 Unidentified On CTS signal is high - device ready to send data LED4 Unidentified Off CTS signal is low LED5 Unidentified On RTS signal is high LED5 Unidentified Off RTS signal is low LED6 Unidentified On Data is being transmitted LED6 Unidentified Off Data is not being transmitted